Yunika resin A HC-U type (striking type) HC-20U
お気に入り機能をご利用いただくにはログインが必要です。
閉じる
【order ID】7633009
【basic item number】HC20U*************************8018
【brand name】UNIKA CO., LTD.
【minimum order quantity】1Pcs
【packages】10
【manufacturer name】UNIKA CO., LTD.
【Country of origin】England
【Weight】79G
[Features]
●Bolts and rebars can be cut into pieces.
●The unique glass tube shape reduces the number of HAMMER CASTER blows.
●Using vinyl ester resin with high alkali resistance, long-term storage before construction is possible.
[Use]
●Foundation work such as steel frames.
●Road construction.
- Tunnel construction.
●Installation work for vibrating machinery.
【specification】
- Outer diameter (mm): 21.5
- Total length (mm): 175
-Capacity ([[CM 3]]): 52.0
-Capacity (ml): 52.0
- Bolts used (deformed steel bar): M20, W3/4 (D19)
- Drill diameter (deformed steel bar) (mm): 25.0 (25.0)
- Drilling depth (mm): 180
- Tensile maximum load (kN): 117.6
- Long-term allowable tensile load (kN): 24.7
- Short-term allowable tensile load (kN): 37.1
[Specification 2]
●Implanting type
[Material/Finish]
Main agent: vinyl ester resin
[Set contents/accessories]
-
【Note】
●The maximum tensile load is the value when the concrete strength FC = 21N/mm [[square of]].
●Bolts and rebars can be cut into pieces.
●The unique glass tube shape reduces the number of HAMMER CASTER blows.
●Using vinyl ester resin with high alkali resistance, long-term storage before construction is possible.
[Use]
●Foundation work such as steel frames.
●Road construction.
- Tunnel construction.
●Installation work for vibrating machinery.
【specification】
- Outer diameter (mm): 21.5
- Total length (mm): 175
-Capacity ([[CM 3]]): 52.0
-Capacity (ml): 52.0
- Bolts used (deformed steel bar): M20, W3/4 (D19)
- Drill diameter (deformed steel bar) (mm): 25.0 (25.0)
- Drilling depth (mm): 180
- Tensile maximum load (kN): 117.6
- Long-term allowable tensile load (kN): 24.7
- Short-term allowable tensile load (kN): 37.1
[Specification 2]
●Implanting type
[Material/Finish]
Main agent: vinyl ester resin
[Set contents/accessories]
-
【Note】
●The maximum tensile load is the value when the concrete strength FC = 21N/mm [[square of]].