[Features] ●Does not use Freon or other refrigerants. ●There is no driving part, and almost no maintenance is required. ●Compact and easy to install. ●The air that has been heat-exchanged inside the panel is automatically exhausted. ●The maximum ambient temperature for installation is 80°C. ●Can be used in dusty environments.
[Use] ●To prevent troubles with control panels and electronic devices. ● Cooling of the control panel. ● Cooling of industrial cameras. ● Cooling of the sensor box.
【specification】 ● Air consumption (L/min): 460 to 980 - Connection diameter: NPT-1/4 ● Compressed air supply port: NPT-1/4 - Maximum working pressure (MPa): 1.0 ● Working air pressure (MPa): 0.27 to 0.69 Working pressure (MPa): 0.27 to 0.69 - Total length (mm): 272 Applicable fluid: Compressed air (compressor air)
[Specification 2] ● Air consumption (NL/min) 460 to 980: 0.27 MPa to 069 MPa ● Cooling capacity (w) 282 to 600: 0.27 MPa to 069 MPa ●Continuous cool air discharge type - With vinyl hose for internal piping