[Features] By using DPD reagent or potassium iodide reagent, residual chlorine concentrations (free residual chlorine, combined residual chlorine, total residual chlorine) of 2.0 to 10 mg/L can be measured. If you already have the "Residual Chlorine Meter DPD Method" main unit, you can use it in the same way by purchasing only the medium concentration color plate and replacing it. The reagents used (DPD reagent, potassium iodide reagent) are the same as those used in the "Residual Chlorine Meter DPD Method." In order to prevent the proliferation of Legionella bacteria, which cause Legionnaires' disease, classified as a Category 4 infectious disease, To achieve this, it is necessary to regularly manage the hygiene of facilities and equipment. It helps control the residual chlorine concentration used for disinfection.
[Applications] For controlling the concentration of combined chlorine monochloramine (approximately 3 mg/L) used to disinfect bath water For controlling the concentration of chlorine disinfectant (5-10mg/L) in circulating bathtub piping For controlling the concentration of chlorine (5-10mg/L) used in chemical cleaning of cooling towers
【specification】 Width(mm):67 Depth (mm): 37 Height (mm): 156 Measurement range (mg/L): 2.0 to 10 Test volume (ml): Approx. 50 Measurement method: DPD method; Measurement range: 2.0-10mg/L (6 levels); Standard colorimeter plate: 2.0 3.0 4.0 5.0 7.0 10; DPD powder reagent not included; Dimensions: Main unit: 67 (W) x 37 (D) x 156 (H) mm; Vinyl case: 97 (W) x 50 (D) x 170 (H) mm; Weight: 0.3 kg (including case)
[Specification 2] Like the "Residual Chlorine Meter DPD Method," this measuring device uses a simple measurement method based on the reaction between the residual chlorine in the test water and the DPD reagent, resulting in a pale reddish-purple color. By using a dedicated medium concentration colorimeter, concentrations from 2.0 to 10 mg/L can be measured in six steps. Free residual chlorine is measured using DPD reagent, and then total residual chlorine can be measured by adding potassium iodide reagent. The difference between the total residual chlorine concentration and the free residual chlorine concentration is used to determine the monochlorine concentration. It is possible to calculate the combined residual chlorine concentration such as min.
[Material/Finish] -
[Set contents/accessories] Residual chlorine measuring device (with colorimetric plate for medium concentration) x 1 unit Square test tubes with silicone caps x 3 Vinyl case x 1
【Note】 -
regular price
¥13,000
Selling price
¥13,000
regular price
Salesold out
unit price
/Around
tax included
Use the right and left arrows to navigate the slideshow, or swipe left or right if using a mobile device
Selecting a selection results in a full page refresh.
Press the spacebar and then the arrow keys to select.