【manufacturer name】NIDEC TECHNO MOTOR CORPORATION,
【Country of origin】Japan
【Weight】26KG
[Features] ● Two HDGT-18P class units can be used simultaneously with a high power output capacity of 13kVA. ●Equipped with a high-performance general-purpose inverter for improved reliability and maintainability. ●Restart operation is easy due to the configuration of the reset button at the time of trip. ●Built-in earth leakage circuit breaker (corresponds to leakage current).
[Use] -
[Specifications] ● Input side voltage: 3-phase AC 200 V, 220 V ● Input side frequency: 50 Hz/60 Hz, 60 Hz ● Output side voltage: 3-phase AC 200 V ● Input side power supply capacity: 17.0 kVA ● Output side frequency: 400 Hz ● Output Side output capacity: 13.0kVA
[Specification 2] ● Power ON/OFF switch ● Supports history investigation of operation stoppages (for repair and diagnosis) ● Power cord length: 3 m ● Inverter control method: Sine wave PWM method
[Material/Finish] -
[Set contents/accessories] -