[Features] ● High voltage UNIT for static electricity removal hyper series. ●A high voltage abnormality is detected by the abnormality detection circuit. ●The ion balance can be easily adjusted with the adjustment volume.
[Specification 2] ●Operating temperature/humidity: 0 to 50°C/10 to 90% RH (no freezing or condensation) Storage temperature/humidity: -30 to 70°C/10 to 90% RH (no freezing or condensation) -Rated input voltage: DC24V±10% ●Variable output range without load (rms): AC output 4kV/DC output -150 to +550V ●Secondary short-circuit current: 5mA or less ●Output monitor: Output 1/1000V±5% of the output voltage to the monitor terminal ●Low voltage detection: When the output is about 85% or less of each output setting voltage, such as when the high voltage is shortened or when an abnormal spark occurs, an abnormality detection operation is performed. ● Power input connector: Molex 5569-04A1-210 -High voltage output connector: Ceramic high voltage output terminal (2 pieces) ●Alarm output terminal: C contact relay output
[Material/Finish] - Housing: SPCC, white paint
[Set contents/accessories] -
【Note】 ●Be sure to read the instruction manual for safe use of the product. ●Be careful of condensation. Doing so may cause an electric shock or malfunction. ●Never use the product in an area that requires an explosion-proof structure. ● Since high voltage is applied to the discharge needle, do not bring tools, metals such as wires, fingers, hands, or face close to it. ●As this product applies high voltage, do not expose it to water, oil, solvent, etc.